How to Install Wood-Grain Fiber Cement Lap Siding
Lap siding is laid in horizontal rows, called courses. Each course covers the top edge of the one below. The visible height of a course is its exposure. Set that dimension on the elevation before ordering planks: it determines how many rows fit below a window and how much wall each pack will cover.
DPW plank dimensions and coverage
The DPW wood-grain plank sold by Khoshkechin is 200 mm wide, 2,400 mm long and 8 mm thick. It is supplied unpainted in packs of six. One plank has a face area of 0.48 m², so the pack contains 2.88 m² of material before overlap or cutting.
For a run of six full planks, the nominal installed coverage is 6 × 2.40 m × the specified exposure in metres. For ordering, draw each course across the elevation and mark the end joints, corners and openings. Two walls with the same area can need different numbers of planks if their cuts cannot be reused. Use the approved lap for the actual product; the retail dimensions alone do not establish it.
Installation sequence
1. Check the rails and the drainage path
Check the steel rails for alignment and confirm that plank ends and specified fixing points land on supports. Correct an uneven rail before cladding it; an error in the support plane can remain visible along several courses. On light steel framing, use the project wall section alongside the LSF cladding guide.
Trace how rain passing behind the siding will drain at the base of the wall and at openings. Coordinate the water-resistive layer, flashings and cavity with the wall design. A vapor-control layer has a different function and should not be substituted solely because it is called a barrier.
2. Set the starter and mark the courses
Mark a level line for the first course and transfer the course heights to both ends of the wall. Check where the rows meet window heads and sills before fixing the starter. Install the specified starter strip or profile so the bottom plank sits at the intended angle. Follow the project detail for ground clearance and drainage at the base.
3. Fix the planks and check the lap
Install the first plank level. Select fasteners for the plank, the steel support and the exposure conditions. Use the board system’s fixing schedule for screw position, edge distance and spacing. A screw hidden by the next course can still be too close to the plank edge.
Work upwards, measuring the exposed height at both ends of each course. Check the run against the original marks periodically so that small variations do not accumulate across the wall. Set out end joints according to the elevation and the approved support detail.
4. Finish corners, openings and cut edges
At an inside or outside corner, check how the specified trim meets both runs of siding before cutting the final plank. At windows, make sure flashing discharges water to the exterior. Apply sealant only where the detail calls for it; leave drainage and movement openings clear.
DPW’s wood grain is a surface texture, not a factory-applied paint finish. Follow the specified coating system for faces and cut edges. Test the finish on an offcut to see how the colour and sheen look across the raised grain before painting the elevation.
Materials available from Khoshkechin
| Product | Size and sales unit | Use | Store |
|---|---|---|---|
| DPW wood-grain fiber cement plank | 200 × 2,400 × 8 mm; six planks per pack | Unpainted siding; calculate quantities using installed exposure | View and buy DPW siding |
| Jotashield Alkali Resistant Primer | 18 L per pail | Primer for cement-based surfaces where specified in the coating system | View primer and contact sales |
| Jotashield ColourLast Silk | 18 L per pail | Exterior acrylic finish for a compatible, prepared surface | View finish and contact sales |
Frequently asked questions
Does one pack cover 2.88 m² of finished wall?
No. That figure is the combined face area of six planks. The overlap hides part of each plank, and cuts around corners and openings affect the order quantity.
What overlap should I use for the 200 mm DPW plank?
The store listing gives the plank width but does not establish an approved overlap. Obtain the installation detail for the selected system before marking the courses. Once the overlap is confirmed, subtract it from 200 mm to find the exposed height of a typical full course.
What information is needed for a siding estimate?